Setting the Ethernet Converter IP Address
As the Ethernet Converter is pre-configured before shipping,
the most common setup that has to be performed is to set the IP
Address of the converter to meet your network requirements. The
standard RS232 serial interface is used to setup the device.
The parameters to be used for this interface are:
Baud Rate - 19200
Parity - None,
Data bits - 8,
Stop bits – 1,
Flow control – None.
Using any data terminal emulation program, such as Hyper-terminal
(standard with Windows) or Telix, you can view and edit the converter
parameters.
To configure the Ethernet Converter using Hyper-Terminal, proceed
as follows:
- Start the program
from the Windows START/ PROGRAM/ ACCESSORIES/ COMMUNICATIONS/
HYPER TERMINAL menu option.
- Type in an appropriate name for the new
connection, i.e. TNAJBox. Select the OK button.
- Use the Connect using select box and select
an available serial Comm’s port and then click on the OK
button.
- Enter the port settings as illustrated
below. Note that the Configuration Port is set to a transmission
speed of 19200 Bits per second.
- Click on OK. When the Terminal
Session connects, type in Reboot and press the keyboard
[Enter] key.
- The EtherPAD will now reboot. At the
Password prompt, type in xxx.

Note:The current firmware version
will also be displayed.
- Press the keyboard [C] key to configure
the TCP/IP module.
- At the Your option? prompt,
press the [B] key twice.
9. When the BOOTP Parameters Menu is displayed,
press the [I] keyboard “hot-key”.
Note: The
above addresses are only examples and they must be set according
to your specific network.
- At the prompt, type in the required IP
address as follows:
- The first set of 3 numbers and then
press the [Enter] key,
- The second set of 3 numbers and then
press the [Enter] key.
- The third set of 3 numbers and then
press the [Enter] key.
- The last set of 3 numbers and then
press the [Enter] key.
- Press the [Q] key to return to
the Configuration Menu.
- Once all the parameters have been configured
correctly, press the [Q] key and the following will
be displayed.
- Press the [S] key to save the parameters.
Once saved, the following will be displayed.
- Pressing the [Q] key at this stage
will reboot the device and enable the saved settings.
Note: Wait
approximately 15 to 20 seconds after the device has rebooted before
attempting to establish a TCP/IP connection. |